Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Biomolecules ; 13(2)2023 02 14.
Article in English | MEDLINE | ID: covidwho-2241570

ABSTRACT

The emergence of the recent pandemic causing severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has created an alarming situation worldwide. It also prompted extensive research on drug repurposing to find a potential treatment for SARS-CoV-2 infection. An active metabolite of the hyperlipidemic drug fenofibrate (also called fenofibric acid or FA) was found to destabilize the receptor-binding domain (RBD) of the viral spike protein and therefore inhibit its binding to human angiotensin-converting enzyme 2 (hACE2) receptor. Despite being considered as a potential drug candidate for SARS-CoV-2, FA's inhibitory mechanism remains to be elucidated. We used molecular dynamics (MD) simulations to investigate the binding of FA to the RBD of the SARS-CoV-2 spike protein and revealed a potential cryptic FA binding site. Free energy calculations were performed for different FA-bound RBD complexes. The results suggest that the interaction of FA with the cryptic binding site of RBD alters the conformation of the binding loop of RBD and effectively reduces its binding affinity towards ACE2. Our study provides new insights for the design of SARS-CoV-2 inhibitors targeting cryptic sites on the RBD of SARS-CoV-2.


Subject(s)
COVID-19 , Fenofibrate , Humans , SARS-CoV-2/metabolism , Protein Binding , Spike Glycoprotein, Coronavirus/chemistry , Molecular Dynamics Simulation
2.
Build Environ ; 219: 109212, 2022 Jul 01.
Article in English | MEDLINE | ID: covidwho-1944381

ABSTRACT

The Delta variant of SARS-CoV-2 has inflicted heavy burdens on healthcare systems globally, although direct evidence on the quantity of exhaled viral shedding from Delta cases is lacking. The literature remains inconclusive on whether existing public health guidance, based on earlier evidence of COVID-19, should respond differently to more infectious viral strains. This paper describes a study on an outbreak of the Delta variant of COVID-19 in an auditorium, where one person contracted the virus from three asymptomatic index cases sitting in a different row. Field inspections were conducted on the configuration of seating, building and ventilation systems. Numerical simulation was conducted to retrospectively assess the exhaled viral emission, decay, airborne dispersion, with a modified Wells-Riley equation used to calculate the inhalation exposure and disease infection risks at the seat level. Results support the airborne disease transmission. The viral emission rate for Delta cases was estimated at 31 quanta per hour, 30 times higher than those of the original variant. The high quantity of viral plume exhaled by delta cases can create a high risk zone nearby, which, for a mixing ventilation system, cannot be easily mitigated by raising mixing rates or introducing fresh air supply. Such risks can be reduced by wearing an N95 respirator, less so for social distancing. A displacement ventilation system, through which the air is supplied at the floor and returned from the ceiling, can reduce risks compared with a mixing system. The study has implications for ventilation guidelines and hygiene practices in light of more infectious viral strains of COVID-19.

3.
Interface Focus ; 12(2): 20210063, 2022 Apr 06.
Article in English | MEDLINE | ID: covidwho-1713822

ABSTRACT

Poor housing conditions are known to be associated with infectious diseases such as high Coronavirus disease 2019 (COVID-19) incidences. Transmission causes of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in poor housing conditions can be complex. An understanding of the exact mechanism of transmission can help to pinpoint contributing environmental issues. Here, we investigated a Hong Kong COVID-19 outbreak in early 2021 in four traditional Tong Lau houses with subdivided units. There are more than 80 subdivided units of less than 20 m2 floor area each on average. With a total of 34 confirmed COVID-19 cases, the outbreak had an attack rate of 25.4%, being one of the highest attack rates observed in Hong Kong, and ranked among the highest attack rates in reported outbreaks internationally. Tracer gas leakage and decay measurements were performed in the drainage system and in the subdivided units to determine the transport of infectious aerosols by the owner-modified sophisticated wastewater drainage pipe networks and the poor ventilation conditions in some subdivided units. The results show that the outbreak was probably due to multiple transmission routes, i.e. by the drainage pipe spread of stack aerosols, which is enhanced by poor ventilation in the subdivided units.

4.
J Hazard Mater ; 430: 128475, 2022 05 15.
Article in English | MEDLINE | ID: covidwho-1676810

ABSTRACT

Vertical transmission of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) along a vertical column of flats has been documented in several outbreaks of coronavirus disease 2019 (COVID-19) in Guangdong and Hong Kong. We describe an outbreak in Luk Chuen House, involving two vertical columns of flats associated with an unusually connected two-stack drainage system, in which nine individuals from seven households were infected. The index case resided in Flat 812 (8th floor, Unit 12), two flats (813, 817) on its opposite side reported one case each (i.e., a horizontal sub-cluster). All other flats with infected residents were vertically associated, forming a vertical sub-cluster. We injected tracer gas (SF6) into drainage stacks via toilet or balcony of Flat 812, monitored gas concentrations in roof vent, toilet, façade, and living room in four of the seven flats with infected residents and four flats with no infected residents. The measured gas concentration distributions agreed with the observed distribution of affected flats. Aerosols leaking into drainage stacks may generate the vertical sub-cluster, whereas airflow across the corridor probably caused the horizontal sub-cluster. Sequencing and phylogenetic analyses also revealed a common point-source. The findings provided additional evidence of probable roles of drainage systems in SARS-CoV-2 transmission.


Subject(s)
COVID-19 , Aerosols , COVID-19/epidemiology , Disease Outbreaks , Housing , Humans , Phylogeny , SARS-CoV-2
5.
J Hazard Mater ; 421: 126799, 2022 01 05.
Article in English | MEDLINE | ID: covidwho-1336648

ABSTRACT

Stack aerosols are generated within vertical building drainage stacks during the discharge of wastewater containing feces and exhaled mucus from toilets and washbasins. Fifteen stack aerosol-related outbreaks of coronavirus disease 2019 (COVID-19) in high-rise buildings have been observed in Hong Kong and Guangzhou. Currently, we investigated two such outbreaks of COVID-19 in Hong Kong, identified the probable role of chimney effect-induced airflow in a building drainage system in the spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). We injected tracer gas (SF6) into the drainage stacks via the water closet of the index case and monitored tracer gas concentrations in the bathrooms and along the facades of infected and non-infected flats and in roof vents. The air temperature, humidity, and pressure in vertical stacks were also monitored. The measured tracer gas distribution agreed with the observed distribution of the infected cases. Phylogenetic analysis of the SARS-CoV-2 genome sequences demonstrated clonal spread from a point source in cases along the same vertical column. The stack air pressure and temperature distributions suggested that stack aerosols can spread to indoors through pipe leaks which provide direct evidence for the long-range aerosol transmission of SARS-CoV-2 through drainage pipes via the chimney effect.


Subject(s)
Aerosols , Air Microbiology , COVID-19 , Housing , COVID-19/transmission , Hong Kong , Humans , Phylogeny , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL